How to connect multi-vibration controller?

Views: 219 Author: Site Editor Publish Time: Origin: Site

Hardware Connection

Familiar with the various operating precautions, you can follow the steps below to connect the instrument and install software:

1. Connect Vibration controllers Abort with the Synchronous box via synchronizing cable. The Abort port of the host controller must be connected to the Input port of the synchronization box, the Output ports of the synchronization box connected to the Abort port of following slave controllers. As shown in Figure 1.

image.png

Figure 1

2. Connect vibration controller LAN with Router one by one through the network cable. As shown in Figure 2.

image.png

Figure 2

3. Connect computer and router through the network cable. As shown in Figure 3.

image.png

Figure 3

4. The host Vibration controller’s output (Drive) connects with the input-end of power amplifier.

5. Connect vibration controller with transducers and power amplifier with Shaker. As shown in Figure 4.


级联.png

Figure 4